Simeken PRO Waste Wood Trial Air Emissions Results (1)

Parameter Measured Value Measurement Test Method USEPA Stack test Method (2) Max. Permissible Limit (2)
Sulphur Dioxide (SO2) 9.45 mg/m3 3.61 ppm NMX-AA-055-1979 USEPA-19 30 Parts per million (Volume)
35.32 mg/m3 13.48 ppm
Carbon Monoxide (CO) 6.57 mg/m3 6.57 mg/m3 USEPA-10-1996 USEPA-3/3A 63 mg/m3
7.11 mg/m3 7.11 mg/m3
Nitrous Oxides (NOx) 1.40 mg/m3 0.74 ppm USEPA-7E-1998 USEPA-3/3A 500 Parts per million (Volume)
77.27 mg/m3 40.63 ppm
Particulates (PSTs) 6.24 mg/m3 6.24 mg/m3 NMX-AA-10-2001 USEPA-5 24 mg/m3
19.73 mg/m3 19.73 mg/m3
Hydrogen Chloride (HCl) Not Detected Not Detected NMX-AA-070-1980 USEPA-26 25 Parts per million (Volume)
7.11 mg/m3 4.77 ppm
Lead (Pb) 0.013 mg/m3 0.013 mg/m3 USEPA-29-1998 USEPA-29 0.2 mg/m3
< 0.011 mg/m3 < 0.011 mg/m3
Cadmium (Cd) < 0.002 mg/m3 < 0.002 mg/m3 USEPA-29-1998 USEPA-29 0.02 mg/m3
0.0014 mg/m3 0.0014 mg/m3
Mercury (Hg) Not Detected Not Detected USEPA-29-1998 USEPA-29 0.08 mg/m3
< 0.00007 mg/m3 < 0.00007 mg/m3
Dioxins and Furans (3) 0.0430 ng EQT/m3 0.0430 ng /m3 USEPA-23A-1996 USEPA-23 13 ng/m3
Opacity Not Tested Not Tested Not Applicable USEPA-9 10 percent
Fugitive Ash Not Tested Not Tested Not Applicable USEPA-22 No visual > hour

Notes:

(1) Results obtained via two functional test performed by independent third part lab Ecotech Laboratories of Libramiento Emillio Portes Gil #2021 entre Loma Bonita y Gema Col. La Joya, H. Matamoros, Tam., Mexico, and ABC laboratories of Jacarndas No. 15. San Clemente, Alvaro Obregon, Mexico, D.F. 01740, on May 10, 2005 and May 25, 2005 respectively.

(2) Per Title 40 of the US Code of Federal Regulations Part 60 Subpart AAAA. The comparisons of the trial results from Mexico with subpart AAAA is based on the fact that both sets of results are calculated using 7% Oxygen and extremely similar test methods.

(3) Dioxins and furans were tested and results were obtain via independent third party, ABC laboratories of Jacarndas No. 15. San Clemente, Alvaro Obregon, Mexico, D.F. 01740, on June 30, 2005.